Frigidaire FH30DD50MS Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Cuisine Frigidaire FH30DD50MS. FRIGIDAIRE FH30DD50MS User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
TABLE OF CONTENTS
www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352
All about the
Installation
and
Use & Care
of your Telescoping
Downdraft Ventilation
System
Welcome & Congratulations ...................................2
Important Safety Instructions ................................. 3
Shipping Pack .......................................................4
Product Dimensions ...............................................5
Planning ...............................................................6
316902913 (June 2012) Rev. D
Installation ...........................................................9
Use & Care .........................................................13
Before You Call ...................................................15
Major Appliance Warranty ....................................16
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Use & Care

TABLE OF CONTENTSwww.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352All about theInstallationandUse & Car

Page 2 - This unit is intended for

104. Install Duct Transition to Blower Install the duct transition on the blower, using the three wide head Phillips screws. It is recommended for al

Page 3 - IMPORTANT SAFETY INSTRUCTIONS

DUCT TAPE OVER SEAM AND SCREWScrewAir FlowDuct Tape Over Seam and ScrewDUCT ON-THE-FLOORDUCT THROUGH-THE-FLOOR116. Install Ductwork- Use galvanized or

Page 4 - SHIPPING PACK

DUCT PIECESEQUIVALENT LENGTH XNUMBER USED =EQUIVALENT LENGTH6" (15.2cm) Round Straight **1 Ft. (0.3m) Ft. or m6" (15.2cm) Round Metal F

Page 5 - PRODUCT DIMENSIONS

13Operating the Telescoping Downdraft System- Raise the downdraft by pressing the raise/lower push button. The telescoping vent will rise up to full h

Page 6 - PLANNING

14Cleaning the Telescoping Downdraft VentWARNINGIt is advised to disconnect power from the downdraft when cleaning to minimize risk of electrical shoc

Page 7

15BEFORE YOU CALL (Solutions to Common Problems)OCCURRENCE POSSIBLE CAUSE/SOLUTIONTelescoping Vent does not fully raiseCheck for and remove obstructio

Page 8

16MAJOR APPLIANCE WARRANTYThis warranty does not cover the following:1 Products with original serial numbers that have been removed, altered or canno

Page 9

Do not, under any circumstances, cut, remove, or bypass the grounding prong.Power supply cord with 3-prong grounding plugGrounding type wall receptacl

Page 10 - INSTALLATION

3IMPORTANT SAFETY INSTRUCTIONSWARNINGTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:•Use this unit only in t

Page 11

Tools You Will Need• Phillips Screwdriver• 1/4” Nut Driver / Ratchet• Tape Measure• Carpenter Square• Vertical Level or Plum Line• Tools r

Page 12

5PRODUCT DIMENSIONSModel A B C D E RiseFH30DD50MS 30” (76.2 cm) 26 7/8” (68.3 cm)17 13/16” (45.2 cm)34 5/16” (87.2 cm)2 3/16” (5.5 cm)10” (25.4 cm)FH3

Page 13 - USE & CARE

6PLANNINGBasic InformationA qualied technician must complete the installation of this appliance. This downdraft blower system is designed to be used

Page 14

7Plan the DuctworkThis downdraft blower system is designed for use with 3¼ x 10” ductwork (can be transitioned to 6” round).For best performance, choo

Page 15 - IMPORTANT

8Plan the Electrical ConnectionThe downdraft blower system draws 2.8 AMPS and requires a 120 VAC, 60 Hz circuit.The unit has a 28 inches long power co

Page 16 - MAJOR APPLIANCE WARRANTY

91. Cut Countertop Opening- Lay out and cut the cooktop cut-out far enough forward so downdraft will t behind it (refer to cooktop installation instr