Frigidaire FHWC3640MS Manuel du propriétaire Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 17
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
5
LIST OF MATERIALS
LIST OF MATERIALS
Parts included in your hood
4 - 0.45 x 1.3 cm mounting screws
2 - .35 x .65 cm rectangular vent transition
mounting screws
2 - .29 x .65 cm round metal mounting plate
mounting screws
” x 10” (8.3 x 25.4 cm) rectangular metal vent
system.
7” (17.8 cm) round metal mounting plate.
Parts Needed
2 - UL listed wire connectors
Wall or roof cap with damper to match vent system
Vent clamps/duct tape as required
UL listed or CSA approved ½” strain relief
Tools/Materials required
Drill
1¼(3.0 cm) drill bit
(0.3 cm) drill bit for pilot holes
Pencil
Wire stripper or utility knife
Tape measure or ruler
Caulking gun and weatherproof
caulking compound
Flat-blade screwdriver
Phillips screwdriver
Saber or keyhole saw
For cabinets with recessed bottoms:
Two - 2” (5.1 cm) wide ller strips. Length and
thickness determined by recess dimensions.
Four at head wood screws or machine screws
with washers and nuts (to attach ller strips).
ELECTRICAL REQUIREMENTS
Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 (latest edition), or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edi-
tion) and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that
the ground path is adequate.
A copy of the above code standards can be obtained
from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical
circuit is required.
If the house has aluminum wiring, follow the
procedure below:
Connect a section of solid copper wire to the
pigtail leads.
Connect the aluminum wiring to the added
section of copper wire using special co
nectors and/or tools designed and UL listed
for joining copper to aluminum.
Follow the electrical connector manufacturer’s recom-
mended procedure. Aluminum/copper connection must
conform with local codes and industry accepted wiring
practices.
Wire sizes and connections must conform with
the rating of the appliance as specied on the
model/serial rating plate.
The model/serial plate is located on the left side of
the range hood.
Wire sizes must conform to the requirements of
the National Electrical Code, ANSI/NFPA 70 (la
est edition), or CSA Standards C22. 1-94, Canad
an Electrical Code, Part 1 and C22.2 No. 0-M91
(latest edition) and all local codes and ordinances.
1.
2.
Vue de la page 4
1 2 3 4 5 6 7 8 9 10 ... 16 17

Commentaires sur ces manuels

Pas de commentaire