Frigidaire FFRE1833U2 Schéma de câblage Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 9
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
3
Installation Instructions
Remove Air Conditioner from Cabinet
NOTE: Remove any packaging material from cabinet exterior.
1
1. Pull down on front grille from upper edge. Lift front grille upwards and place to one side. (See FIG.1)
2. Remove filter. To remove, grasp in the middle on each side. Bow filter out to detach top edge from tabs. Once top
is free, lift filter up and out.
3. Locate the four Front Panel screws and remove. These screws will be needed to re-install the Front Panel later
(See FIG.2)
4. Push metal cabinet side inward to release plastic tabs on each side of Front Panel (see Fig. 3).
5. Rotate Front Panel up until top tabs are free. Pull panel straight out. Depress latch on electronics plug (on some
models) to disconnect.
6. Remove Front Panel from unit (see Fig. 4).
7. Remove shipping screws from top of unit and also on both sides by the base (See FIG.5). For BY model there
is only 1 shipping screw on the right side of the base.
8. With the aid of an assistant, hold the cabinet while pulling on the base pan handle (see FIG. 4), and carefully
remove the air conditioner from cabinet.
9. For BN models add two foam inserts to holes in top of cabinet where shipping screws were removed from. (See FIG.6)
10. BN models come with internal shipping packaging.
THIS PACKAGING AND PLASTIC TIES MUST BE REMOVED PRIOR TO INSTALLING THE AIR CONDITIONER
BACK INTO THE CABINET. (See FIG.7)
11. Remove plastic wrapping from all points on power cord.
Install Top Angle Rail
2
1. Remove adhesive strip coating from foam gasket. Attach adhesive side of gasket to bottom of top angle rail. Insert 4
screws from inside of cabinet and secure to top angle rail. (See FIG. 8)
Assemble Window Filler Panels
3
1. If the side retainer is not installed on the window filler panel, slide the “I” section at
the end of the window filler panel into side retainer. (See FIG. 9)
2. Place cabinit on floor, a bench or a table. Slide top and bottom legs of window filler
panels frame into channel in the top and botton angle rails.
3. From inside of cabinet insert 3 screws to attach each side retainer. (See FIG. 10)
Window Mounting
FIG.1
FIG.2
FIG.6
FIG.3
Shipping Packaging
Plastic tie
Front Grille
FIG.7
Foam Gasket
Top angle rail
FIG.8
FIG.5
shipping
screws
FIG.4
base pan handle
Vue de la page 2
1 2 3 4 5 6 7 8 9

Commentaires sur ces manuels

Pas de commentaire