Plan the Electrical Connection
The downdraft blower system draws 2.8 AMPS and requires
a 120 VAC, 60 Hz circuit.
The unit has a 28 inches long power cord with a 3 pronged
plug. Plan to provide a grounded outlet in a location which
will allow the unit’s power cord to reach.
PLANNING
NOTE
If the 30” model is being installed in a 30” wide cabinet
or the 36” model in a 36” wide cabinet, the outlet cannot
be located on the back wall of cabinet.
Outlet may also be wall-mounted with access hole in
cabinet.
Recommended Electrical
Outlet Locations
(All Shaded Areas)
All vertical dimensions relative to top surface of the countertop.
All horizontal dimensions relative to cutout in the countertop.
Ensure that access to the electrical outlet will not be blocked by
the ducting after installation.
Electrical Outlet Location
Model M - From Center
FH30DD50MS 13 ½” (34.3 cm)
FH36DD50MS 16 ½” (42.0 cm)
7-7/8”
(20 cm)
8-3/4”
(22.2 cm)
M M
6-1/2”
(16.5 cm)
19-1/16”
(48.4 cm)
23-3/4”
(60.3 cm)
4-5/8"
(11.8 cm)
9-1/2"
(24.1cm)
14-3/4"
(37.5 cm)
22-1/8"
(56.2 cm)